12 volt electric ball valve CWX-15N

12 volt electric ball valve CWX-15N

Description

12 volt electric ball valve BSP NPT flow control valve actuator ball valve

★ Can work in boiler water room, good substitution for solenoid valve

1. Metal gearbox and POM gear design, low noise, perform reliably 

2. Long service life: more than 100000 circles

3. Electric limit and machinery limit design, located accurately, avoid gear run continuously. 

4. Mufti-angle assembling, easy to install

5. Float ball structure, no leakage,especially suitable for heavy pollution conditions.

1. Heat energy meters, fire work, save water system

2. Auto control system, industrial mini auto control equipment

3. Water saving equipment, drinking water equipment

4. Air-conditioning fan coil(HVAC)

12 volt electric ball valve

 

Product model

 

 

Rated voltage

 

 

Working current

 

 

Output torque

 

 

Open/close time

 

 

Control mode

 

 

CWX-15Q

CWX-15N

 

 

DC3-6V
DC12V
AC/DC9-24V
AC220V
AC85-265V

 

 

Max100mA

(CR04 except Max150mA)

 

 

Max1.5NM

Max2.0NM

 

 

<3s

<5s

 

 

CR01 CR02 CR02+  

CR03 CR03A  CR04

CR05

 

 

 

Working pressure

 

 

Power

 

 

Medium temperature

 

 

Valve size

 

 

IP Grade

 

 

Product life time

 

Max1.0Mpa<3W0-100℃DN8-DN20

DN8-DN32

IP65100000 times

12 volt electric ball valve

      CR01(two wires and reverse polarity )

        

      Voltage:DC3-6V/12V/9-24V

     1.Connecting SW to OPEN , the valve opens , getting the
     position ,automatically power off, the valve remains fully
     open position
     2.Connection SW to CLOSE , the valve close , getting the                 
     position ,automatically power off, the valve remains fully   
       close position
     CR02 (three wires two point control)

      Voltage:DC3-6V/12V/ 9-24V/AC220V
      1.Connecting SW to OPEN, the valve opens , getting the
      position ,automatically power off, the valve remain fully
      open position
      2.Disconnecting SW to CLOSE, the valve close , getting
      the position and automatically power off, the valve remains
      fully close position
      Note:AC24V/AC220V can only be used for CWX-50K series
      electric valves

 

      CR02+(three wires two point and fail-safe/power-off return) 

      Voltage:DC 9-24V  

      1.Connecting SW to OPEN, the valve opens , getting the
      position and automatically power off, the valve remains
      fully open position
      2.Disconnecting SW to CLOSE, the valve close , getting
      the position and automatically power off, the valve remains
      fully close position
      Note:As the power-off and valve will be return
      automatically,and RD/G(B)/Y(B) 3wires can not be power-on
      together to keep valve safe
      CR03(three wires one point control)

      Voltage:DC3-6V/12V /ADC9-24V /AC220V

      1.Connecting SW, the valve opens , getting the position,
      automatically power off, the valve remains fully open position
      2.Disconnecting SW, the valve close , getting the position,
      automatically power off, the valve remains fully close
      position
      Note:When power is DC voltage and Red Wires is “+”,
      Blue wire is “—”

 

      CR03A( three wires one point control with “-“)  

      Voltage ADC9-24V

      1.Connecting SW, the valve opens, getting the position,
      automatically power off, the valve remains fully open
      position
      2.Disconnecting SW, the valve close, getting the position,
      automatically power off, the valve remains fully close
      position
      CR04(two wires and fail-safe/power-off return) 

      Voltage:DC3-6V/ADC9-24V/AC220V

      1.SW connecting ,the valve open, getting the position and
      the power off automatically,the valve remains fully open/close
      position
      2.SW disconnecting ,the valve close, getting the position
      and power off automatically,the valve remains fully open/close
      position

12 volt electric ball valve

      CR05(five wires micro controller with signal feedback)

      Voltage:DC3-6V/12V/24V

     CR05   wiring description 

     1.Connecting SW and OPEN , the valve opens , getting
       the position green wire output the OLS signal , the
       controller test the signal OLS, connect SW to STOP,
       the valve stops and remains fully open position
     2.Connecting SW and CLOSE , the valve close , getting
       the position red wire output the CLS signal , the
       controller test the signal CLS, connect SW to STOP,
       the valve stops and remains fully close position,
     Note:Please make sure the signal wires “red”,”black” and
        “green” be connected at first,then connect the power
         wires ” yellow” and “blue”

Lucy Liu
______________________________________
Tianjin Tianfei High-Tech valve Co., Ltd.
Address:NO.16 Rongyuan Road, 300384,Tianjin, China
Email : [email protected] / Web:https://www.valveelectric.com
Phone:+86-18702234196 (Whatsapp / Wechat)